Cartridge Heater

 


CARTRIDGE HEATER


The cartridge heater is of pipe form, from one end of which lead wires are drawn out. Effective heating is obtained simply by inserting it into the substance to be heated.

ILF standard cartridges (metric series)
Cat No. Dia. Watts Volts Length Cat No. Dia. Watts Volts Length
ILF65000 6.5 100 230 40 ILF65013 6.5 125 230 80
ILF65001 6.5 125 230 40 ILF65014 6.5 '180 230 80
ILF65015 6.5 280 230 80
ILF65005 6.5 100 230 50
ILF65006 6.5 160 230 50 ILF65017 6.5 160 230 100
ILF65018 6.5 220 230 100
ILF65009 6.5 125 230 60 ILF65019 6.5 350 230 100
ILF65010 6.5 200 230 60
Cat No. Dia. Watts Volts Length Cat No. Dia. Watts Volts Length
ILF80020 8.0 100 230 40 ILF80037 8.0 180 230 100
ILF80021 8.0 160 230 40 ILF80038 8.0 280 230 100
ILF80039 8.0 400 230 100
ILF80024 8.0 125 230 50
ILF80025 8.0 200 230 50 ILF80040 8.0 250 230 130
ILF80041 8.0 400 230 130
ILF80028 8.0 100 230 60
ILF80029 8.0 140 230 60
ILF80030 8.0 220 230 60
ILF80033 8.0 160 230 80
ILF80034 8.0 200 230 80
ILF80035 8.0 315 230 80
Cat No. Dia. Watts Volts Length Cat No. Dia. Watts Volts Length
ILF10042 10.0 100 230 40 ILF10062 10.0 220 230 100
ILF10043 10.0 125 230 40 ILF10063 10.0 350 230 100
ILF10044 10.0 200 230 40 ILF10064 10.0 560 230 100
ILF10047 10.0 100 230 50 ILF10067 10.0 315 230 130
ILF10048 10.0 160 230 50 ILF10068 10.0 500 230 130
ILF10049 10.0 250 230 50 ILF10069 10.0 800 230 130
ILF10052 10.0 125 230 60 ILF10070 10.0 400 230 160
ILF10053 10.0 180 230 60  LF10071 10.0 630 230 160
ILF10054 10.0 315 230 60
ILF10057 10.0 160 230 80
ILF10058 10.0 250 230 80
ILF10059 10.0 400 230 80
Cat No. Dia. Watts Volts Length Cat No. Dia. Watts Volts Length
ILF10072 12.5 100 230 40 ILF10092 12.5 250 230 100
ILF10073 12.5 160 230 40 ILF10093 12.5 400 230 100
ILF10074 12.5 250 230 40 ILF10094 12.5 630 230 100
ILF10077 12.5 100 230 50 ILF10097 12.5 400 230 130
ILF10078 12.5 200 230 50 ILF10098 12.5 630 230 130
ILF10079 12.5 315 230 50 ILF10099 12.5 1000 230 130
ILF10082 12.5 125 230 60 ILF10101 12.5 500 230 160
ILF10083 12.5 200 230 60 ILF10102 12.5 800 230 160
ILF10084 12.5 315 230 60 ILF10103 12.5 1250 230 160
ILF10087 12.5 200 230 80 ILF10104 12.5 630 230 200
ILF10088 12.5 315 230 80 ILF10105 12.5 900 230 200
ILF10089 12.5 500 230 80
Cat No. Dia. Watts Volts Length Cat No. Dia. Watts Volts Length
ILF10106 16.0 100 230 40 ILF10130 16.0 500 230 130
ILF10107 16.0 250 230 40 ILF10131 16.0 700 230 130
ILF10132 16.0 1100 230 130
ILF10110 16.0 160 230 50
ILF10111 16.0 250 230 50 ILF10135 16.0 630 230 160
ILF10112 16.0 400 230 50 ILF10136 16.0 900 230 160
ILF10137 16.0 1600 230 160
ILF10115 16.0 160 230 60
ILF10116 16.0 250 230 60 ILF10139 16.0 800 230 200
ILF10117 16.0 400 230 60 ILF10140 16.0 1250 230 200
ILF10141 16.0 2000 230 200
ILF10120 16.0 230 230 80
ILF10121 16.0 400 230 80 ILF10142 16.0 1000 230 250
ILF10122 16.0 630 230 80 ILF10143 16.0 1600 230 250
ILF10125 16.0 350 230 100 ILF10144 16.0 1250 230 300
ILF10126 16.0 500 230 100 ILF10145 16.0 1800 230 300
ILF10127 16.0 800 230 100
Cat No. Dia. Watts Volts Length Cat No. Dia. Watts Volts Length
ILF10146 20.0 200 230 60 ILF10166 20.0 800 230 160
ILF10147 20.0 315 230 60 ILF10167 20.0 1100 230 160
ILF10148 20.0 500 230 60 ILF10168 20.0 1800 230 160
ILF10151 20.0 350 230 80 ILF10170 20.0 1600 230 200
ILF10152 20.0 500 230 80 ILF10171 20.0 1600 230 200
ILF10153 20.0 800 230 80 ILF10172 20.0 2500 230 200
ILF10156 20.0 450 230 100 ILF10173 20.0 1250 230 250
ILF10157 20.0 630 230 100 ILF10174 20.0 2000 230 250
ILF10158 20.0 1000 230 100
ILF10175 20.0 1600 230 300
ILF10161 20.0 630 230 130 ILF10176 20.0 2200 230 300
ILF10162 20.0 900 230 130
ILF10163 20.0 1400 230 130

Points to be observe when using cartridge heaters


  1. for cartridge heaters with surface loads up to 20W/cm the receiving hole must be drilled with small tolerance and a sliding fit is necessary.
  2. the drilled recieving bores for cartridge heaters must be cylindrical, crossing bores and shringkages cause a localisation of heat and shorgen the useful life of the heating elements.
  3. the end of the cartridge heater with the connection lead should be protected against liquid and pasty media (lubricants, oil, synthetic materials, etc) because otherwise leakage currents and, possibly flashover could occur at the outlet connection terminals.
  4. the connection leads should be protected against mechanical vibrations close to the outlet of the cartridge heater.
  5. if possible, control of the operating temperature shoud be realised by means of continuous regulators, by controllers with pulse widht modulation or electronic power control device. a control system with long timelag often causes thermal overload of the heating elements. for this reason also the temperature sensor must be fitted in close proximity to the cartridge heater about 10mm apart.
  6. when using several cartridge heaters the distance between two consecutive cartridge shoudl be at least equal to the cartridge diameter.
  7. if heating elements are to be stored for long periods they should be housed in absolutely dry roms or enclosed in plastic bags which are hermetialy sealed.

TEMPERATURE SENSOR


Thermocouple is made by joining two dissimilar metal conductors together to form a closed circuit. when one end is maintained at constant temperature and the other end is exposed, thermal electromotive force is generated in the circuit.

Thermocouple is installed directly int he process medium, which can be corroseve and at high temperature.

A variety of thermocouple wire types is available to cover the range of temperature from -184 to 2330C.

Thermocouple wires are generally selected to provide as linear as possible a temperature-emf relation.