Finned Air Heaters

 

FINNED AIR HEATERS


APPLICATION
For air heating installations requiring electric heat such as forced air duct heating, recirculating drying ovens, packaged air conditioning equipment, convecto heaters, load testing equipment, as well as any other air heating application where the sheath temperature does not exceed 400 ° C.

CONSTRUCTION
Our elements are manufactured in the following materials as standard:
Stainless steel element with stainless steel fin.
Other sheaths and fin materials may be used, provided these are available and suitable for manufacturing finned heating elements.
To ensure long life it is important to select the correct materials and KW rating required for each application.
Please consult our engineering office when considering the design of any new requirement.

BENDING

Our finned heating elements can be bent in any shape provided the final formation is mechanically pratical. There are, however, limiting tolerances as well as maximum and minimum bending radii which must be respected. Since over bending can cause elements to break or crack, we recommend that all elements are bent in our workshops. Tooling already exist for bending the more common customes' requirements, but in certain cases, particularly for multibent elements, it is for elements to have close tolerances after being bent, our sales department will advise on special tooling costs.

MOUNTING
Our finned heating elements may be fitted with any terminals or maounting arrangements. Customers fitting elements in their own equipment should ensure that they are well spaced across the duct face and if mounted in rows are staggered. Care should also be taken to ensure adequate clearance exists between the element and the air duct wall. The layout of the elements can materially effect resistance to airflow and pressure drop through the system. Our engineering department are available to advise customers.

FINNED AIR HEATERS
Air Heating Elements

ILF Finned Air Elements come complete with standard stake-on bushes.
Mounting bushes are fixed to each end of U, W or Triple U form elements, While Straight elements have one fixed and one floating bush.

31 Kw per Sq.Metre Series, Max. Sheath Temp 400°C at 20°C Ambient.
Nominal Sheath Diameter 8.2 mm, Nominal Fin Diameter 26 mm.

Straight Length

'U' FORM

'W' FORM

Cat. No.
240 Volt

Watts

Dim
'A'

Cat. No.
240 Volt

Watts

Dim
'A'

Cat. No.
240 Volt

Watts

Dim
'A'

ILF61-MS

500

760

ILF61-MU

500

360

ILF61-MW

500

190

ILF62-MS

750

1065

ILF62-MU

750

515

ILF62-MW

750

265

ILF63-MS

1000

1425

ILF63-MU

1000

695

ILF63-MW

1000

355

ILF64-MS

1500

2015

ILF64-MU

1500

990

ILF64-MW

1500

505

ILF65-MS

1800

2400

ILF65-MU

1800

1180

ILF65-MW

1800

600

ILF66-MS

2000

2650

ILF66-MU

2000

1305

ILF66-MW

2000

660

ILF67-MS

2400

3160

ILF67-MU

2400

1560

ILF67-MW

2400

790
46.5 Kw per Sq. Metre Series. Min. recommended Air Velocity 1.0 m/s
                                                       Max. Sheath Temp. 400°C at 20°C Ambient.
Nominal Sheath Diameter 8.2 m, Nominal Fin Diameter 26 mm
Straight Length 'U' FORM 'W' FORM
Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim
'A'
ILF10-MS 600 630 ILF10-MU 600 295 ILF12-MW 1000 240
ILF11-MS 750 755 ILF11-MU 750 360 ILF13-MW 1250 295
ILF12-MS 1000 965 ILF12-MU 1000 465 ILF14-MW 1500 345
ILF13-MS 1250 1175 ILF13-MU 1250 570 ILF15-MW 1750 405
ILF14-MS 1500 1380 ILF14-MU 1500 670 ILF16-MW 2000 460
ILF15-MS 1750 1630 ILF15-MU 1750 795


ILF16-MS 2000 1835 ILF16-MU 2000 900


77 Kw per Sq. Metre Series. Min. recommended Air Velocity 2.0 m/s
                                                    Max. Sheath Temp. 400°C at 20°C Ambient.
Nominal Sheath Diameter 8.2 m, Nominal Fin Diameter 26 mm
Straight Length 'U' FORM 'W' FORM
Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim
'A'
ILF41-MS 600 390 ILF41-MU 600 175 ILF43-MW 1200 185
ILF42-MS 900 540 ILF42-MU 900 250 ILF44-MW 1500 220
ILF43-MS 1200 735 ILF43-MU 1200 350 ILF45-MW 1800 260
ILF44-MS 1500 885 ILF44-MU 1500 425 ILF46-MW 2000 285
ILF45-MS 1800 1035 ILF45-MU 1800 500 ILF47-MW 2400 335
ILF46-MS 2000 1135 ILF46-MU 2000 550 ILF48-MW 3000 420
ILF47-MS 2400 1340 ILF47-MU 2400 650 ILF49-MW 3600 500
ILF48-MS 3000 1680 ILF48-MU 3000 820 ILF50-MW 4800 650
ILF49-MS 3600 2000 ILF49-MU 3600 980


ILF50-MS 4800 2610 ILF50-MU 4800 1285


108 Kw per Sq. Metre Series. Min. recommended Air Velocity 3.0 m/s
                                                    Max. Sheath Temp. 400°C at 20°C Ambient.
Nominal Sheath Diameter 8.2 m, Nominal Fin Diameter 26 mm
Straight Length 'U' FORM 'W' FORM
Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim
'A'
ILF21-MS 600 440 ILF21-MU

600

200 ILF25-MW 1800 190
ILF22-MS 900 440 ILF22-MU 900 200 ILF26-MW 2000 210
ILF23-MS 1200 545 ILF23-MU 1200 255 ILF27-MW 2400 245
ILF24-MS 1500 660 ILF24-MU 1500 310 ILF28-MW 3000 300
ILF25-MS 1800 760 ILF25-MU 1800 360 ILF29-MW 3600 350
ILF26-MS 2000 835 ILF26-MU 2000 400 ILF30-MW 4800 460
ILF27-MS 2400 990 ILF27-MU 2400 475


ILF28-MS 3000 1205 ILF28-MU 3000 585


ILF29-MS 3600 1420 ILF29-MU 3600 690


ILF30-MS 4800 1850 ILF30-MU 4800 905


ILF Finned Air Elements come complete with standard stake-on bushes.
Mounting bushes are fixed to each end of U, W or Triple U form elements,

While Straight elements have one fixed and one floating bush.

31 Kw per Sq.Metre Series, Max. Sheath Temp 400°C at 20°C Ambient.
Nominal Sheath Diameter 11.2 mm, Nominal Fin Diameter 29 mm.

Straight Length

'U' FORM

'W' FORM

Cat. No.
240 Volt

Watts

Dim
'A'

Cat. No.
240 Volt

Watts

Dim
'A'

Cat. No.
240 Volt

Watts

Dim
'A'

ILF61-FS

500

585

ILF61-FU

500

275

ILF62-FW

750

205

ILF62-FS

750

815

ILF62-FU

750

390

ILF63-FW

1000

265

ILF63-FS

1000

1045

ILF63-FU

1000

505

ILF64-FW

1500

390

ILF64-FS

1500

1545

ILF64-FU

1500

755

ILF65-FW

1800

460

ILF65-FS

1800

1820

ILF65-FU

1800

895

ILF66-FW

2000

500

ILF66-FS

2000

2000

ILF66-FU

2000

985

ILF67-FW

2400

600

ILF67-FS

2400

2390

ILF67-FU

2400

1160




46.5 Kw per Sq. Metre Series. Min. recommended Air Velocity 1.0 m/s
                                                       Max. Sheath Temp. 400°C at 20°C Ambient.
Nominal Sheath Diameter 11.2 m, Nominal Fin Diameter 29 mm
Straight Length 'U' FORM 'W' FORM
Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim
'A'
ILF10-FS 600 460

ILF10-FU

600 215 ILF12-FW 1000 190
ILF11-FS 750 560 ILF11-FU 750 265 ILF13-FW 1250 220
ILF12-FS 1000 750 ILF12-FU 1000 360 ILF14-FW 1500 270
ILF13-FS 1250 860 ILF13-FU 1250 415 ILF15-FW 1750 295
ILF14-FS 1500 1065 ILF14-FU 1500 515 ILF16-FW 2000 335
ILF15-FS 1750 1160 ILF15-FU 1750 565 ILF17-FW 2250 385
ILF16-FS 2000 1340 ILF16-FU 2000 655 ILF18-FW 2500 415
ILF17-FS 2250 1530 ILF17-FU 2250 750 ILF19-FW 2750 460
ILF18-FS 2500 1660 ILF18-FU 2500 815 ILF20-FW 3000 490
ILF19-FS 2750 1840 ILF19-FU 2750 905


ILF20-FS 3000 1960 ILF20-FU 3000 965


77 Kw per Sq. Metre Series. Min. recommended Air Velocity 2.0 m/s
                                                       Max. Sheath Temp. 400°C at 20°C Ambient.
Nominal Sheath Diameter 11.2 m, Nominal Fin Diameter 29 mm
Straight Length 'U' FORM 'W' FORM
Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim
'A'
ILF41-FS 600 310

ILF42-FU

900 195 ILF45-FW 1800 200
ILF42-FS 900 420 ILF43-FU 1200 270 ILF46-FW 2000 220
ILF43-FS 1200 575 ILF44-FU 1500 325 ILF47-FW 2400 255
ILF44-FS 1500 680 ILF45-FU 1800 380 ILF48-FW 3000 320
ILF45-FS 1800 795 ILF46-FU 2000 415 ILF49-FW 3600 380
ILF46-FS 2000 865 ILF47-FU 2400 490 ILF50-FW 4800 495
ILF47-FS 2400 1015 ILF48-FU 3000 620


ILF48-FS 3000 1275 ILF49-FU 3600 740


ILF49-FS 3600 1515 ILF50-FU 4800 965


ILF50-FS 4800 1960





93 Kw per Sq. Metre Series. Min. recommended Air Velocity 2.8 m/s
                                                       Max. Sheath Temp. 400°C at 20°C Ambient.
Nominal Sheath Diameter 11.2 m, Nominal Fin Diameter 29 mm
Straight Length 'U' FORM 'W' FORM
Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim'A' Cat. No.
240 Volt
Watts Dim
'A'
ILF21-FS 1000 460

ILF21FU

1000 215 ILF24-FW 2000 190
ILF22-FS 1200 460 ILF22-FU 1200 215 ILF25-FW 2500 215
ILF23-FS 1500 560 ILF23-FU 1500 265 ILF26-FW 3000 270
ILF24-FS 2000 760 ILF24-FU 2000 365 ILF27-FW 3500 295
ILF25-FS 2500 860 ILF25-FU 2500 415 ILF28-FW 4000 335
ILF26-FS 3000 1070 ILF26-FU 3000 520 ILF29-FW 5000 425
ILF27-FS 3500 1160 ILF27-FU 3500 565 ILF30-FW 6000 490
ILF28-FS 4000 1340 ILF28-FU 4000 655


ILF29-FS 5000 1685 ILF29-FU 5000 825


ILF30-FS 6000 1960 ILF30-FU 6000 965